Trotec LD Pulse Generator
Designed for use with the Trotec LD6000 combi Leak Detection system, the pulse wave generator creates a periodically recurring pressure wave, which can detected acoustically above the line by the LD6000.
The LD-Pulse Generator connects to pipe networks to create a pressure wave that can acoustically be detected by the LD6000 when used with a large ground microphone.
The wave expands and has a distance reach of up to 600 metres, in optimum conditions.
The LD6000 is equipped with a special pulse mode, where the volume and frequency of the pulse are optimally represented and can be determined seperate to other noise related detection signals.
This system is ideal for non-metallic water pipes, which can be detected precisely even to a depth of two metres without the need of shutting networks down.
This way, piping diagrams can quickly and safely be created, complemented and checked. This method can be used to compile, complete or check plans and pipe layouts or networks.
Specifications
- Minimum pressure: 2 bar (29 psi) (minimum pressure of the service pipes)
- Operating time: approx. 12 hours
- Pulse sequence: approx. 60 per minute
- Connection: 1-inch GEKA high pressure coupling
- Power supply: Internal battery (rechargeable) or 230V AC
- Weight: 4.2 kg
Packages
Product | Details | Price |
---|---|---|
Trotec LD Pulse Generator |
EMAIL sales@accurate.kiwi FOR LATEST PRICING
|